EVALUATION OF THE BLOOD PRESSURE DETERMINATION TROUGH SMARTPHONE LINKED EQUIPMENT IN HEALTHY YOUNG INDIVIDUALS
DOI:
https://doi.org/10.5380/rmu.v1i4.40689Keywords:
Blood pressure determination, smartphone, self-measurement blood pressure.Abstract
Nowadays, smartphones are increasingly gaining space in the medical environment, the scientific evaluation of the real efficacy and reproducibility of this new technology is essential. In this context, our goal was to evaluate, unprecedently in our country, the smartphone linked sphygmomanometer (Withings Blood Pressure Monitor) with other methods (mercury, aneroid and digital sphygmomanometers). 45 healthy medical students were randomly selected from UFPR (Universidade Federal do Paraná), and three measures by each modality were taken and compared between them, in random order and on each person. The preference for self-measurement method between digital and smartphone linked sphygmomanometers was also evaluated. The obtained data were analyzed through paired t-Student and oneway Anova models, with significance of p<0,05. We obtained 576 measures; in the individual comparison of them, in relation to the systolic blood pressure (SBP), when equipments were confronted between each other, the smartphone didn’t present significant difference with the other methods (p>0,05), be in each measure by student or between methods. Regarding diastolic blood pressure (DBP), there was significant difference between smartphone’s measurements in relation to all other equipments (p<0,05). In the specific analysis of the repeated means in each student by each method, the smartphone was the only one to significantly differ of the other techniques, existing variability among each measure. Concerning the preference analysis, the matters of measurement time, discomfort of the compressive cuff and visual presentation didn’t significantly influence the final choice, in which 51,9% chose the smartphone and 29,6% the digital.
References
VI Diretrizes Brasileiras de Hipertensão Arterial - VI DBHA. Rev. Bras Hipertens. 2010; 17:1-64.
IV Diretriz para uso da Monitorização Ambulatorial da Pressão Arterial. II Diretriz para uso da Monitorização Residencial da Pressão Arterial IV MAPA/II MRPA. Arq Bras Cardiol. 2005; 85(Suppl 2):1-18.
PICKERING TG, WHITE W.B. When and How to Use Self (Home) and Ambulatory Blood Pressure Monitoring. Journal of the American Society of Hypertension, v. 4, p.56 – 51, 2010.
O’Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001;322: 531–6
Barroso WKS, Jardim PCBV, Porto LB, Araújo FA, Sousa AL, Salgado CM. Comparação e Correlação entre Automedida, Medida Casual e Monitorização Ambulatorial da Pressão Arterial. Arq. Bras. Cardiol.;97(2): 148-155. Disponível em: www.arquivosonline.com.br/2011/AOP/aop06811_port.pdf
Agarwal R, Bills JE, Hecht TJW, Light RP. Role of Home Blood Pressure in Overcoming Therapeutic Inertia and Improving Hypertension Control. A Systematic Review and Meta-Analyses. Hypertension. 2011; 57:29-38.
Verberk WJ, Kroon AA, Lenders JWM, et al. Self-Measurement of Blood Pressure at Home Reduces the Need for Antihypertensive Drugs. A Randomized, Controlled Trial. Hypertension. 2007; 50: 1019-1025.
Association for the Advancement of Medical Instrumentation. American National Standard: Electronic or Automated Sphygmomanometers. Arlington, VA: AAMI; 1993.
O’Brien E, Atkins N, Stergiou G et al; on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International Protocol revision 2010 for the Validation of Blood Pressure Measuring Devices In Adults. Blood Press Monit. 2010; 15:23–38.
Inmetro.gov.br [Internet]. Procedimentos para verificação de esfigmomanômetros mecânicos. Maio, 2008. Disponível em: http://www.inmetro.gov.br/ftp_hp/kits/niedimel006r02.pdf
Inmetro.gov.br [Internet]. Procedimentos para verificação e inspeção de esfigmomanômetro digital. Abril, 2011. Disponível em: http://www.inmetro.gov.br/ftp_hp/kits/NIE-Dimel-097-Rev04.pdf.
Cooper, S. Physician smartphone adoption rate to reach 81% in 2012. Manhattan Research. In press 2009. Disponível em: http://manhattanresearch.com/News-and-Events/Press-Releases/physician-smartphones-2012
Mosa AS, Yoo I, Sheets L. A systematic review of healthcare applications for smartphones. BMC Med Inform Decis Mak, v. 12, p. 67, 2012. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/22781312.
Sarasohn-kahn J. How smartphones are changing health care for consumers and providers Oakland, CA: California HealthCare Foundation; April, 2010. Disponível em: http://www.chcf.org/publications/2010/04/how-smartphones-are-changing-health-carefor-consumers-and-providers.
Withings. The Smart Blood Pressure Monitor: User Manual. Versão 3.2, p. 23-24, 2012.
Topouchian J et al. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol. Vasc Health Risk Manag, v. 10, p. 33-44, 2014. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/24476688
Whitings.com [Internet]. Blood Pressure Monitor. Disponível em: http://vitrine.withings.com/blood-pressure-monitor.html
Center for Disease Control and Prevention. Youth and Tobacco Use. February, 2014. Disponível em: http://www.cdc.gov/tobacco/data_statistics/fact_sheets/youth_data/tobacco_use/index.htm
Caspersen CJ, Pereira MA, Curran KM. Changes in physical activity patterns in the United States, by sex and cross-sectional age. Med Sci Sports Exerc 2000;32:1601-9.
Krishna S, Boren SA, Balas EA. Healthcare via cell phones: a systematic review. Telemed J E Health, v. 15, n. 3, p. 231-40, Apr 2009. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/19382860.
Omboni S, Guarda A. Impact of home blood pressure telemonitoring and blood pressure control: a meta-analysis of randomized controlled studies. Am J Hypertens, v. 24, n. 9, p. 989-98, Sep 2011. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/21654858.
Mcgillicuddy JW et al. Mobile Health Medication Adherence and Blood Pressure Control in Renal Transplant Recipients: A Proof-of-Concept Randomized Controlled Trial. JMIR Res Protoc, v. 2, n. 2, p. e32, 2013. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/24004517
Krishna S, Boren SA, Balas EA. Healthcare via cell phones: a systematic review. Telemed J E Health, v. 15, n. 3, p. 231-40, Apr 2009. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/19382860
O'brien E et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit, v. 7, n. 1, p. 3-17, Feb 2002. ISSN 1359-5237. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/12040236
Omron Healthcare Inc. Monitor Automático de La Presión Arterial con Brazelete Comfit, Modelo HEM-781INT: Manual de Instrucciones. P.27, 2005.
Downloads
How to Cite
Issue
Section
License
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).