DETERMINATION OF PESTICIDES IN WATER BY LIQUID CHROMATOGRAPHY-(ELECTROSPRAY IONIZATION)-MASS SPECTROMETRY (LC-ESI-MS)

Autores

  • SONIA C. N. QUEIROZ
  • KAREL LAZOU
  • PAT SANDRA
  • ISABEL C. S. F. JARDIM

DOI:

https://doi.org/10.5380/pes.v14i0.3123

Palavras-chave:

MULTIRRESÍDUO, PESTICIDAS-CONTAMINAÇÃO, MULTIRESIDUE, PESTICIDES-CONTAMINATION.

Resumo

Desenvolveu-se método para a determinação de selecionado grupo de pesticidas em água (de torneira e subterrânea), usando cromatografia em fase líquida (ionização do tipo electrospray) espectrometria de massas (CL-IE-EM). Os pesticidas dimetoato, carbaril, simazina, atrazina, ametrina, tebutiuron, diuron e linuron foram isolados por meio de extração líquidolíquido com diclorometano e analisados em coluna de fase reversa, tipo C-18, com eluição por gradiente e vazão de 1 mL min-1. Foram obtidas recuperações nas faixas de 89% a 112% (R.S.D. ≤ 10%) para água de torneira e de 76 a 98% (R.S.D. ≤ 6%) para água subterrânea. O procedimento de enriquecimento, que pré-concentra amostras em 500 vezes, seguido do uso de monitoramento seletivo de íon (modo SIM) forneceu limite de quantificação suficientemente baixo para atender a legislação internacional (0,1 µg.L-1). O método desenvolvido mostrou-se prático, eficiente e confiável para a determinação dos pesticidas selecionados em amostras de água.

DETERMINAÇÃO DE PESTICIDAS EM ÁGUA POR CROMATOGRAFIA EM FASE LÍQUIDA (IONIZAÇÃO DO TIPO ELECTROSPRAY)-ESPECTROMETRIA DE MASSAS (CL-IE-EM)

Abstract

A method for determination of a selected group of pesticides in water (tap and ground water) was developed using liquid chromatography-(electrospray ionization)-mass spectrometry (LC-ESI-MS). The pesticides dimethoate, carbaryl, simazine, atrazine, ametryne, tebuthiuron, diuron and linuron were isolated using liquid-liquid extraction with dichloromethane and analyzed on a reversed phase column, C-18, with gradient elution at flow rate of 1 mL. min-1. Recoveries ranged from 89% to 112% (R.S.D. ≤ 10%) for tap water and from 76% to 98% (R.S.D ≤ 6%) for ground water. The enrichment procedure, followed by use of the selected ion monitoring (SIM) mode gave quantification limits low enough to reach the international legislation level of 0.1 µg.L-1, with a 500-fold preconcentration. The method developed is practical, efficient and reliable for the determination of the selected group of pesticides in the water samples.

Downloads

Como Citar

QUEIROZ, S. C. N., LAZOU, K., SANDRA, P., & JARDIM, I. C. S. F. (2004). DETERMINATION OF PESTICIDES IN WATER BY LIQUID CHROMATOGRAPHY-(ELECTROSPRAY IONIZATION)-MASS SPECTROMETRY (LC-ESI-MS). Pesticidas: Revista De Ecotoxicologia E Meio Ambiente, 14. https://doi.org/10.5380/pes.v14i0.3123

Edição

Seção

Artigos