SENSITIVE ANALYSIS OF A COAL COMBUSTION MODEL ON A DROP TUBE FURNACE

Authors

  • L. Zimmer Universidade Federal do Rio Grande do Sul
  • F. M. Pereira Universidade Federal do Rio Grande do Sul
  • P. S. Schneider Universidade Federal do Rio Grande do Sul

DOI:

https://doi.org/10.5380/reterm.v12i2.62045

Keywords:

Drop Tube Furnace, coal combustion, sensitivity analysis

Abstract

In the present work a one-dimensional model for coal combustion in a Drop Tube Furnace (DTF) is developed. The equations that characterize the flow, heat transfer phenomena and coal combustion reactions are programmed in a FORTRAN90 language code. The results are compared with a reference model and experimental data, showing good agreement. A sensitivity study is performed to understand the behavior of coal combustion due to changes of some working parameters of the DTF. From the variation of the oxygen concentration, working temperature and input flow rates the response of the coal combustion in terms of unburned fraction can be obtained.

Downloads

Published

2013-12-31

How to Cite

Zimmer, L., Pereira, F. M., & Schneider, P. S. (2013). SENSITIVE ANALYSIS OF A COAL COMBUSTION MODEL ON A DROP TUBE FURNACE. Revista De Engenharia Térmica, 12(2), 51–58. https://doi.org/10.5380/reterm.v12i2.62045

Issue

Section

Ciência/Science